Average Daily Production Rate *      
Water Storage Tank
Install Time
System Efficiency **
Merlin RO
744 gpd
None needed      
1 Hour
24%
Standard RO
10-50 gpd
Integral part of system
Up to 4 Hours *
As little as 5%
*   Based on inlet conditions of 50 psi (3.44 bar), 77°F (25°C), 750 ppm NaCl.
** Efficiency rating is identical to recovery rating when the system is tested without a storage tank or when a storage tank is bypassed.



Condition *
Inlet Pressure
Inlet Temperature      
Inlet TDS
Inlet Hardness
Inlet Chlorine
Inlet Iron
Inlet Manganese
Minimum
40 psi (2.76 bar)
40°F (4.44°C)
50 mg/L
0 mg/L - (0 grain)      
0 mg/L
0 mg/L
0 mg/L
Maximum
80 psi (5.52 bar)
100°F (37.78°C)
2,000 mg/L
171 mg/L - (10 grain)
1.0 mg/L
.1 mg/L
.05 mg/L



* System is designed for use on potable water sources only.